CDF Series – Commercial Downflow Ceiling Heater
IDEAL SPACES | Bathrooms; Offices; Conference Rooms; Lobbies; Waiting Rooms; Enterance Ways
COLORS | White
TEMP RANGE | 45- 90F
CFM |300
RECESSED | 23-3/4″W x 23-3/4″L x 7″D
SURFACE | 16-1/2″W x 20″L x 5-3/4″D
For commercial spaces that need unobtrusive comfort, install this downflow ceiling heater. Deliver powerful warmth to your office, conference room, lobby, waiting room or entranceway.
- Order a surface or recessed enclosure, depending on your ceiling type and available install space. Surface mounting extends only 6 inches into the room, while the recessed enclosure requires only 7 inches of internal clearance
- Optional relays allow you to connect this ceiling heater to your central building management system, so you can control temperatures from one location
- Included thumb pins hold the unit together, freeing both hands for installation on the ceiling surface or within an enclosure
- Choose a narrow pattern to focus heat on one particular area, or a wide pattern to blanket more area. Asymmetrical heating patterns focus output while still providing generous coverage
- The heaters fan waits until the desired temperature is achieved before blowing air into the room, and discharges all residual heat before shutting off
Additional information
CATALOG NUMBER | UPC | KW(1) | VOLTS | AMPS | PHASE(2) | SHIP WT. (lbs.) |
---|---|---|---|---|---|---|
CDF548 | 6 85360 01510 1 | 4/3/2002 | 208 | 19.2/14.2/9.6 | 1 and 3 | 27 lbs. |
CDF542 | 6 85360 01508 8 | 4/3/2002 | 240 | 16.7/12.5/8.3 | 1 and 3 | 27 lbs. |
CDF547 | 6 85360 01509 5 | 4/3/2002 | 277 | 14.4/10.8/7.2 | 1 | 27 lbs. |
CDF558 | 6 85360 01513 2 | 5/3.8/2.5 | 208 | 24.0/18.3/12.0 | 1 and 3 | 27 lbs. |
CDF552 | 6 85360 01511 8 | 5/3.8/2.5 | 240 | 20.8/15.8/10.4 | 1 and 3 | 27 lbs. |
CDF557 | 6 85360 01512 5 | 5/3.8/2.5 | 277 | 18.1/13.7/9.0 | 1 | 27 lbs. |
CATALOG NUMBER | DESCRIPTION | SHIP WT. (LBS.) |
---|---|---|
CDFSE | Surface Mounting Enclosure Only – To Be Used With Above Heater Sections. | 10 |
CDFRE | Recess Mounting Enclosure Only – To Be Used With Above Heater Sections. | 18 |
CDFSENW | Surface mounted Northern White – To Be Used With Above Heater Section. Dim. 20″L x 16 1/2″W x 5 3/4″D. | 10 |
CDFRENW | Recessed mounted Northern White – To Be Used With Above Heater Sections. Dim. 23 3/4″L x 23 3/4W x 7″D. | 18 |
CDFT | Thermostat SPST Range 45 to 95F | 1 |
CDF24R | Relay (Time Delay 45-60 sec. to close when energized) requires 24 volt supply from remote source. | 1 |
CDFR12 | Relay (Time Delay 45-60 sec. to close when energized) requires 120 volt supply from remote source. | 1 |
CDFDS | Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 3, 60 Hz. | 1 |
CDFTK | Trim Ring for mounting on permanent ceiling (cannot be factory installed). | 1 |
CDFTR4 | 208/240V Primary Transformer/24V sec. and 24V holding coil control relay. | 1 |
CDFTR7 | 277V. Primary Transformer/24V sec. and 24V holding coil control relay. | 1 |
(1) Factory wired for highest wattage, field convertible to lower wattages. |
(2) Factory wired 10, field convertible to 30. |