CDF Series – Commercial Downflow Ceiling Heater

IDEAL SPACES | Bathrooms; Offices; Conference Rooms; Lobbies; Waiting Rooms; Enterance Ways

COLORS | White

TEMP RANGE | 45- 90F

CFM |300

RECESSED | 23-3/4″W x 23-3/4″L x 7″D

SURFACE | 16-1/2″W x 20″L x 5-3/4″D

For commercial spaces that need unobtrusive comfort, install this downflow ceiling heater. Deliver powerful warmth to your office, conference room, lobby, waiting room or entranceway.

  • Order a surface or recessed enclosure, depending on your ceiling type and available install space. Surface mounting extends only 6 inches into the room, while the recessed enclosure requires only 7 inches of internal clearance
  • Optional relays allow you to connect this ceiling heater to your central building management system, so you can control temperatures from one location
  • Included thumb pins hold the unit together, freeing both hands for installation on the ceiling surface or within an enclosure
  • Choose a narrow pattern to focus heat on one particular area, or a wide pattern to blanket more area. Asymmetrical heating patterns focus output while still providing generous coverage
  • The heaters fan waits until the desired temperature is achieved before blowing air into the room, and discharges all residual heat before shutting off

Additional information

CATALOG NUMBER UPC KW(1) VOLTS AMPS PHASE(2) SHIP WT. (lbs.)
CDF548 6 85360 01510 1 4/3/2002 208 19.2/14.2/9.6 1 and 3 27 lbs.
CDF542 6 85360 01508 8 4/3/2002 240 16.7/12.5/8.3 1 and 3 27 lbs.
CDF547 6 85360 01509 5 4/3/2002 277 14.4/10.8/7.2 1 27 lbs.
CDF558 6 85360 01513 2 5/3.8/2.5 208 24.0/18.3/12.0 1 and 3 27 lbs.
CDF552 6 85360 01511 8 5/3.8/2.5 240 20.8/15.8/10.4 1 and 3 27 lbs.
CDF557 6 85360 01512 5 5/3.8/2.5 277 18.1/13.7/9.0 1 27 lbs.
CATALOG NUMBER DESCRIPTION SHIP WT. (LBS.)
CDFSE Surface Mounting Enclosure Only – To Be Used With Above Heater Sections. 10
CDFRE Recess Mounting Enclosure Only – To Be Used With Above Heater Sections. 18
CDFSENW Surface mounted Northern White – To Be Used With Above Heater Section. Dim. 20″L x 16 1/2″W x 5 3/4″D. 10
CDFRENW Recessed mounted Northern White – To Be Used With Above Heater Sections. Dim. 23 3/4″L x 23 3/4W x 7″D. 18
CDFT Thermostat SPST Range 45 to 95F 1
CDF24R Relay (Time Delay 45-60 sec. to close when energized) requires 24 volt supply from remote source. 1
CDFR12 Relay (Time Delay 45-60 sec. to close when energized) requires 120 volt supply from remote source. 1
CDFDS Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 3, 60 Hz. 1
CDFTK Trim Ring for mounting on permanent ceiling (cannot be factory installed). 1
CDFTR4 208/240V Primary Transformer/24V sec. and 24V holding coil control relay. 1
CDFTR7 277V. Primary Transformer/24V sec. and 24V holding coil control relay. 1
(1) Factory wired for highest wattage, field convertible to lower wattages.
(2) Factory wired 10, field convertible to 30.