Home » Products » Control Sections

Control Sections

  • Each unit has a selection of optional built-in controls
  • See Specifications for additional information

Additional information

CATALOG NUMBER DESCRIPTION
DBABCSF Control Section, Front Inlet, 35/8 x 6 x 28 long
DBACSB Control Section, Bottom Inlet, 35/8 x 6 x 28 long
SHABCSF Control Section, Front Inlet, 53/8 x 7 x 28 long
SHABCSB Control Section, Bottom Inlet, 53/8 x 7 x 28 long
CSH07BCS1 Commercial Style, 7 High Bottom Inlet/Top Outlet
CSH014BCS1 Commercial Style, 14 High Bottom Inlet/Top Outlet
CSH014BCS3 Commercial Style, 14 High Bottom Inlet/Front Outlet
DSH07BCS1 Commercial Style, 7 High Bottom Inlet/Top Outlet
DSH014BCS1 Commercial Style, 14 High Bottom Inlet/Top Outlet
DSH07BCS2 Commercial Style, 7 High Front Inlet/Top Outlet
DSH014BCS2 Commercial Style, 14 High Front Inlet/Top Outlet
1CB2P30 1Two Pole Circuit Breaker Rated 30 Amps @ 208,
240, 277 VAC.
1CB2P60 1Two Pole Circuit Breaker Rated 60 Amps @ 208,
240, 277 VAC.
1CB3P30 1Three Pole Circuit Breaker Rated 30 Amps @ 208,
240, 277 VAC.
1CB3P60 1Three Pole Circuit Breaker Rated 60 Amps @ 208,
240, 277 VAC.
2CB2P30 2Two Pole Circuit Breaker Rated 30 Amps @ 208,
240, 277 VAC.
2CB2P60 2Two Pole Circuit Breaker Rated 60 Amps @ 208,
240, 277 VAC.
2CB3P30 2Three Pole Circuit Breaker Rated 30 Amps @ 208,
240, 277 VAC.
2CB3P60 2Three Pole Circuit Breaker Rated 60 Amps @ 208,
240, 277 VAC.
CATALOG NUMBER DESCRIPTION
TR24 Low Voltage Transformer, 24V Secondary
Pneumatic Operated Electric SwitchSPDT switch rated
PE 16A @ 120 VAC, 9A @ 208 VAC, 8A @ 240 VAC, 7A @
277 VAC, pilot duty 125 VA @ 24-277 VAC, pressure
0 – 20 psig.
1PDT Single Pole Pilot Duty Thermostat, 60 to 120F
Temperature Range125 VA Rating.
2PDT Two Stage Pilot Duty Thermostat, 60 to 120F
Temperature Range125 VA Rating.
2ST 2-Stage Thermostat 60-120F temperature range, adjustable through outlet grille-tamper-resistant. Available on 2- or 3-element, single phase heaters only.
** R 120V Receptacle Duplex receptacle, 120V/20A, mounting in left or right end cap of 6, 9, 12 or 18-inch filler sections only.
DS Pilot Duty Disconnect SwitchDouble Pole
(Disconnects relay holding coil circuit)
(Zero Voltage Switch Device operating on 10 second time base; controls modulation 0 to max. outputall solid state components.)
M90525A Master SCR Control rated 25 Amps @ 120 – 480VAC
M90548A Master SCR Controls rated 48 Amps @ 120 – 480VAC
M90548A-2 3 phase Master SCR Controls rated 48 Amps @ 120 – 480VAC
S90525A SCR Slave unit controller. Rated 25 Amps.
S90548A SCR Slave unit controller. Rated 48 Amps.
T90613V 0 – 135 ohm controller to regulate MSCR
NOTES:
1 Blank control sections are subject to the same color selections and pricing as the appropriate matching heater.
2 Specify holding coil voltage where applicable.
3 Not available in ASL3 control sections.
4 Rating for ASL3/ASL5 is 16.6A @ 208/240V, 14A @ 277V.